banner



How To Repair Genteq X13 Ecm

Quick Links

EVERGREEN • EM

INSTALLATION GUIDE

A Purple Brand

loading

  Related Manuals for Imperial Genteq Evergreen EM

  Summary of Contents for Regal Genteq Evergreen EM

  • Page 1 EVERGREEN • EM INSTALLATION GUIDE A Royal Brand...
  • Page 2 Genteq'south Evergreen EM is designed to replace OEM X13 ECM motors quickly and easily – with no programming required. Evergreen EM provides the aforementioned comfort, lower utility bills and air quality equally the OEM X13 ECM motor, with less hassle for yous.
  • Page 3: Table Of Contents

    ® Contents Safety Considerations ................1 Introduction/Applications ..............2 Mounting .................... iii-iv Electrical Connections ..............5-10 High Voltage Power Connections ...........6 Low Voltage Signal Connections ..........vii-9 Last Notes..................10 Sequence of Operation ..............xi Rotation Sensing ..................11 Maintenance ..................12 Reliability ....................12 Troubleshooting Guidelines ............13-15 Evergreen EM Motor Specifications ............sixteen Please read the entire instruction manual before starting the installation.
  • Folio four: Safety Considerations

    ® Safety Considerations The following prophylactic alarm symbol is used throughout this manual as a safety consideration for installation and operation of the Evergreen EM motor. This alarm indicates a chancy situation which, if not avoided, could result in serious injury or death. Delight read and observe all of these safety concerns.
  • Folio 5: Introduction/Applications

    ® Introduction and Features The ultra-high-efficiency ECM has become the preferred motor for use in energy-saving HVAC systems. Evergreen EM is made with the same field- proven, loftier-efficiency ECM technology that has been used for more than 20 years in new HVAC equipment. The Evergreen EM was designed to replace directly-drive blower motors in residential and light commercial indoor furnaces, air handlers, and package systems that were designed with a standard ECM motor, such as an X13 or equivalent competitor model.
  • Page six: Mounting

    ® Mounting Always disconnect the main power from the unit beingness serviced before disconnecting any wiring or removing any components. It is as well a good practise to ostend that the ability is off with a meter. Remove the blower section from the HVAC system. Remove the existing ECM motor from the blower section and properly dispose of the motor.
  • Page vii ® Mounting (CONT'D) If a new motor mount is required and the legs do non line up with the original holes in the blower housing, it is required to use a bolt with either a lock washer and nut or a locking nut through the drilled hole(s).
  • Folio 8: Electric Connections

    ® Electrical Connections The unique design of the Evergreen EM allows for multiple speed operation using either 24VAC (18VDC) detached inputs or variable speed, torque control using a PWM controller. The loftier voltage ability terminals, (50) and (N), must be connected to a continuous, united nations-switched power supply.
  • Page ix: High Voltage Power Connections

    ® Electrical Connections High Voltage Power Connections The Evergreen EM is designed for continuous united nations-switched connection to its rated high voltage ability supply. Motor functioning is controlled by low voltage signal inputs. Always confirm the rating on the motor matches the power supply of the arrangement information technology is applied to and/or the motor it is replacing.
  • Page x: Low Voltage Indicate Connections

    ® Electrical Connections Low Voltage Signal Connections (24VAC) Detached Speed Functioning The Evergreen EM has v available speeds using 24VAC control inputs. The inputs of the Evergreen can connect straight to the 24VAC thermostat terminal strip or 24VAC indicate outputs from the HVAC system control lath. DO NOT connect the Low Voltage Bespeak (speed) terminals to the high voltage power supply.
  • Folio 11 ® Electric Connections Low Voltage Signal Connections (18VDC) Detached Speed Functioning The Evergreen EM has 3 available speeds using 18VDC control inputs. Exercise NOT connect the Depression Voltage SIGNAL (speed) terminals to the high voltage power supply. Applying voltage above 23VDC to these terminals volition cause permanent damage to the motor.
  • Page 12 ® Electrical Connections Low Voltage Betoken Connections Variable Speed Torque Control Selection The Evergreen EM tin also be controlled in a variable speed, torque command mode using a PWM (Pulse Width Modulation) control on terminals (C) and (1). The motor volition operate from 10% - 100% output depending on the input from the ECM PWM speed controller.
  • Page 13: Final Notes

    ® Electric Connections Final Notes Retrofit ECM PWM controllers are available from manufacturers, some of which are listed on www.theDealerToolbox.com. Any control that meets the specifications listed on the previous page should operate the Evergreen EM properly. If there are questions regarding a particular add-on control or building automation organization, delight call Evergreen technical support at 866-503-8566.
  • Page 14: Sequence Of Operation

    ® Sequence of Operation Nameplate-rated line voltage is connected to the High Voltage Ability terminals of the motor at all times. This voltage powers the micro- processor and the controls that drive the motor; nonetheless, the motor will only operate when there is a demand on the Low Voltage SIGNAL terminals. 24VAC performance –...
  • Page fifteen: Maintenance

    ® Maintenance The Evergreen EM motor is permanently lubricated and requires no maintenance. Any signs of water impairment on the replaced motor, in the HVAC organisation, or on the Evergreen EM should exist taken very seriously. Fix the water issues immediately.
  • Page 16: Troubleshooting Guidelines

    ® Troubleshooting Guidelines The High Voltage Power terminals (L) and (N) must be connected to nameplate rated voltage at all times. The adequate High Voltage input range is 90-132VAC for 115V models and 180-264VAC for 208-230VAC models. If the motor does not operate, ostend this voltage is present at the motor and make repairs to the HVAC system if information technology is not.
  • Page 17 ® Troubleshooting Guidelines (CONT'D) PWM will operate the motor anytime a proper bespeak is present between terminals (C) and (i). The (C) Mutual terminal must be connected to the PWM controller. Cheque the PWM controller specifications for the appropriate DC bespeak. Check this signal at the motor on last (1). The specifications required by the motor are as follows: 15-23VDC at 67-93Hz or 127 to 199Hz 10% Guaranteed On and 5% Guaranteed Off Duty Bike...
  • Page xviii ® Troubleshooting Guidelines (CONT'D) Connect motor terminals one, 3, & 5 to either 24VAC or 18VDC and Mutual to terminal C. Reconnect the main ability to the HVAC system. Energize motor terminals 1, three, & 5 with either 24VAC or 18VDC and Common to terminal C continuously for a minimum of v minutes.
  • Page 19: Evergreen Em Motor Specifications

    ® Motor Specifications Evergreen EM is an UL and CSA recognized component. The models listed here are all either 115VAC or 208-230VAC. The commanded voltage range is 90-132 VAC for 115VAC models and 180-264VAC for 208-230VAC models. Boosted models may exist available. See theDealerToolbox.com for more than details.
  • Page twenty Need Additional Assistance? Contractor Hotline: 1.866.503.8566 thedealertoolbox.com ® A Purple Make 1946 Due west Cook Route Fort Wayne, IN 46818 1-866-503-8566 thedealertoolbox.com © 2022 Regal-Beloit Corporation Function #8794721MH Rev 2 /thirteen 7377X/11-12/2.5K/BH/TG...

Source: https://www.manualslib.com/manual/2061813/Regal-Genteq-Evergreen-Em.html

Posted by: smithrandead53.blogspot.com

0 Response to "How To Repair Genteq X13 Ecm"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel